Angelcare AC401 Baby Monitor Disassembly.
Инструкция участника сообщества. Мы благодарны участнику нашего сообщества за составление этой инструкции. Она не редактируется сотрудниками iFixit. Опции История Сохранить в избранное Скачать PDF Редактировать Перевод Получить ссылку для общего использования Встроить это руководство Уведомлять меня об изменениях. Введение. hello all, today we will try to repair the angelcare baby monitor. two rechargeable battery's exploded, the acid was around an electric power cable. so there were two problems : 1 bad connection.

2 battery damage. we will check also the second unit. Инструменты. Запчасти. No parts specified.

Шаг 1 Angelcare AC401 Baby Monitor Disassembly. first remove the 2 screws at the green plastic plate. Шаг 2. remove the plastic plate ( battery compartment) you'll see that there are 2 more screws. Remove them. Шаг 3. now gently remove the green plastic plate arrounf the baby monitor ( arround the screen) use a spudger to click it open. Шаг 4. now open the monitor by clicking it open or slide it open. Sometimes its easier to use a spudger.

be carefull for the electric wires. Шаг 5. 2 battery's were exploded so the acid was on the black electric power wire. use a cotton swab with a little bit of destilled water. Шаг 6. remove the 2 PCB's by removing the screws shown in the picture.

Шаг 7. pull the first PCB up and remove the screws of the second PCB. after removing the two PCB's, clean the acid on the PCB. after cleaning the PCB's put it al together again. Шаг 8 second unit. first remove the battery lid. 1 screw. slide it out like you see in picture.

To reassemble your device, follow these instructions in reverse order. To reassemble your device, follow these instructions in reverse order. 6 участников успешно повторили данное руководство. Автор. Kevin D. Участник с: 02.05.2014. 6 259 Репутация. Автор 21 руководств.

Комментариев: 9. Thanks for this. I couldn't figure out how to get the blue clip off without breaking it to clean some dirt on the screen. Googled it, found this, job done. Sometimes the activity of the reference quartz is 11,150 MHz, and the devices do not find each other. I have so repaired the parent module. Dmitriy, the city of Volzhsky.

Hi Dimitriy - I am experiencing the issue with not finding devices each other. How have you fix it ? Is it a matter of replacing the reference quartz with new one ? Hi. At my Angelcare (AC401) parent unit the screen has slowly become worse and worse. At first, parts of the temperature figures dissapeared, then the symbols around and now I no longer see anything. But the unit still works! (And alert me if the baby's crying) What do you think, is there anything I can do or do I need to buy a new one? Hi There.

I’m having the same problem. Did you find a fix or did you buy a new unit?